Power

Battery

Name Description Type Default Unit
READ INTERVAL How often should the battery voltage be read out and checked? Disabled if set to zero. int 5 s

Critical Level

Name Description Type Default Unit
DURATION How long should the specified voltage remain before triggering the ‘vehicle/battery/critical_level’ event. int 180 s
VOLTAGE Specifies the voltage threshold where the device should trigger the ‘vehicle/battery/critical_level’ event and then go into hibernation. To have any effect, this value must be greater than the safety cut-out voltage. float 12.3 V

Firmware

Name Description Type Default Unit
VERSION Version number of the power management firmware. str 1.1.1.0 -
AUTO UPDATE Automatic update of the firmware on the power management chip? bool True -

Modem

Name Description Type Default Unit
POWER SAVE Put modem into lower power mode during sleep? When enabled it is no longer possible to wakup device on SMS. bool True -

Safety Cut-Out

Name Description Type Default Unit
VOLTAGE Specifies at what voltage the device will be forcibly powered off to prevent battery drain. It is never recommended to go below 12.1 volts, as it may damage the battery and shorten its life. str 12.20 V
DURATION How long time should the specified voltage remain before taking effect? It is important that this value is lower than any sleep timer period, otherwise the device can power down normally before this condition is met. int 240 s

Sleep Timer

Event Driven

Name Description Type Default Unit
EVENT REGEX On which event(s) should this sleep timer be enabled? str ^vehicle/engine/stopped -
INTERVAL How long time should the device sleep before waking up again? int 3600 s
DELAY How long delay before the actual shutdown takes effect? int 10 s
PERIOD How long time after the event has triggered should the device go to sleep? int 1800 s
REASON Explanatory reason for sleeping. str engine_stopped -

Inactivity After Sleep

Name Description Type Default Unit
INTERVAL How long time should the device sleep before waking up again? int 7200 s
DELAY How long delay before the actual shutdown takes effect? int 10 s
PERIOD When waking up after sleep, how long time will the device stay awake before going to sleep again? int 300 s

Inactivity Fallback

Name Description Type Default Unit
INTERVAL How long time should the device sleep before waking up again? int 7200 s
DELAY How long delay before the actual shutdown takes effect? int 10 s
PERIOD How long time should the device stay awake until it is powered down due to inactivity? int 300 s

Suppress

Name Description Type Default Unit
EVENT REGEX Which event(s) should disable current sleep timers and prevent new ones from being enabled? str ^vehicle/engine/running -

Wake Trigger

Name Description Type Default Unit
VOLTAGE LEVEL DURATION How long should the specified voltage level be observed before the device powers on? int 3 s
VOLTAGE LEVEL At what voltage level should the device power on? - >13.20 V
VOLTAGE CHANGE DURATION How long should the specified voltage change be observed before the device powers up on engine start? int 1000 ms
VOLTAGE CHANGE How much should the voltage change for the device to power up on engine start? Be careful about changing this parameter too much, as it could prevent your dongle from powering on. str +0.20 V